A failed command answers Err with a message. Most messages are free text from the handler; the codes below are structured, so a binding may match on them.

EPOWERZONE

The command needs hardware behind a power zone that is switched off, so the firmware refused it without running the handler.

EPOWERZONE <zone[,zone...]> <name[,name...]>

Zone numbers are decimal and ascending, and the names follow in the same order with internal spaces replaced by underscores, so the body is always three whitespace-separated tokens:

EPOWERZONE 7,13 SD_Card,NFC/RFID

Switch the zones on (h\p\s, or the Power Zones panel) and call again. A command whose reference page carries no Requires power zone line is never refused this way. A zone the firmware has just been told to switch on counts as on for three seconds, so a call issued immediately after enabling one is not refused while the board manager catches up; before the first zone report arrives after boot, nothing is refused at all.

Power zones

ZoneName
1Sensors
2Display
3Audio
4Sub-GHz
5ESP32
6FPGA
7SD Card
8USB Hub
9Board LED
10LEDs
11Analog
12Aux
13NFC/RFID
14FTDI
15CAN
16Debug CPU
17CM0

Zone 9 drives the board-manager LED rather than a power rail, so no command declares it.